Gas Detection & IAQ · AT

Gas Transmitters — Fixed Gas Detectors, Gas Leak Detectors and Flame Detectors

Pioneer supplies fixed gas transmitters that continuously measure combustible gases (%LEL), toxic gases such as CO, H2S and SO2, oxygen, refrigerants and VOCs, and send a 4–20 mA or digital signal to a control panel, PLC or BMS. The range also covers gas leak detectors and UV, IR and UV/IR flame detectors.

Quotation typically within 48 hoursSupply India and export

Pioneer fixed gas transmitter with alarm beacon and handheld IR remote

Overview

What it does and where it fits.

A gas transmitter is a fixed detector that measures one target gas at one point, continuously, and sends the reading to a control system that raises alarms, starts ventilation or shuts off supply. The sensor technology is chosen by the gas: catalytic bead or infrared for flammable gases, electrochemical cells for toxic gases and oxygen, infrared for CO2, hydrocarbons and many refrigerants, and photoionisation (PID) for VOCs.

Gas leak detectors cover the wider job of finding a leak: fixed alarms in kitchens, gas banks and plant rooms, and portable or ultrasonic detectors for tracing leaks on pipelines and fittings. Flame detectors watch for the ultraviolet or infrared radiation from a flame and respond faster than heat or smoke detectors in open, high-risk areas such as fuel stores and hangars.

Detector placement, calibration and the approvals a site requires matter as much as the detector itself. Where a gas or flame detector forms part of a statutory fire, gas or life-safety system, check the approvals of the specific model against what the authority having jurisdiction requires before specifying it.

Types

  • Combustible gas transmitterMeasures methane, propane, butane, hydrogen and other flammable gases as %LEL, using catalytic bead or infrared sensors.
  • Toxic gas transmitterElectrochemical transmitter for gases such as carbon monoxide, hydrogen sulphide and sulphur dioxide.
  • Oxygen transmitterMonitors oxygen deficiency or enrichment in plant rooms, gas stores and inert-gas areas.
  • Refrigerant gas detectorDetects refrigerant leaks in chiller plant rooms, cold rooms and HVAC/R systems.
  • VOC transmitterPhotoionisation or semiconductor sensing for VOC levels in industrial hygiene and process areas.
  • Gas leak detectorFixed leak alarms and portable, infrared or ultrasonic detectors for locating leaks in pipes, fittings and equipment.
  • Flame detectorUV, IR, UV/IR or multi-spectrum IR detector for fast detection of open flames in high-risk areas.

Features

  • Gas-specific sensor selection: electrochemical, catalytic bead, infrared, PID or semiconductor
  • Diffusion or pumped sampling
  • 4–20 mA, 0–10 V or digital output, by model
  • Audible and visual alarm options
  • Flame detectors with relay, 4–20 mA or digital output and self-test

Applications

  • Gas banks, kitchens and boiler rooms
  • Chiller plant rooms and refrigerant leak detection
  • Oil and gas pipelines, refineries and storage
  • Chemical and pharmaceutical plants
  • Laboratories handling hazardous gases
  • Power plants and substations
  • Aircraft hangars, warehouses and fuel stores
  • Data centres

Specifications

Spec table.

Standard ranges and materials. Tell us your medium, range and connection and we will match the model.

ParameterValue
Target gasesCombustible gases (%LEL), oxygen, toxic gases (e.g. CO, H2S, SO2), refrigerants, VOCs
Gas sensing technologiesElectrochemical, catalytic bead (pellistor), infrared, photoionisation (PID), semiconductor (metal oxide)
SamplingDiffusion or pumped, continuous online monitoring
Output4–20 mA, 0–10 V or digital (Modbus), by model

Gas leak detectors

ParameterValue
Detection principlesSemiconductor, electrochemical, infrared, ultrasonic
FormatsFixed (continuous area monitoring) or portable
AlarmAudible, visual or both

Flame detectors

ParameterValue
Detection principlesUV, IR, UV/IR, multi-spectrum IR
OutputRelay contacts, 4–20 mA or digital, by model
DiagnosticsSelf-test

Measuring range, alarm levels, enclosure and approvals depend on the target gas and model; send the gas list and area classification for a selection.

For consultants

Consultant spec clause.

Paste it into your technical specification or BOQ, then adjust ranges and quantities to your schedule.

gas-transmitters · spec clause
1. Fixed gas detectors (gas transmitters) shall be provided at the locations shown on the drawings for the target gases scheduled: combustible gases in %LEL, toxic gases in ppm, oxygen in % vol and refrigerants.
2. Sensing technology shall suit the target gas: catalytic bead or infrared for combustible gases, electrochemical for toxic gases and oxygen, and infrared [or semiconductor] for refrigerants.
3. Sampling shall be by diffusion [pumped sampling where the detector cannot be placed at the sampling point].
4. Each detector shall have local audible and visual alarm indication and shall give a 4–20 mA [Modbus] output to the gas detection control panel, PLC or BMS.
5. Detectors for lighter-than-air gases shall be mounted near the ceiling and for heavier-than-air gases near the floor, close to likely leak sources and as per the manufacturer's guidance.
6. Detectors installed in classified hazardous areas shall carry Ex marking suitable for the zone, gas group and temperature class; the bidder shall submit the certificate and any statutory approval required for the site.
7. Flame detectors, where scheduled, shall be UV/IR [IR / multi-spectrum IR] type with relay [4–20 mA] output and self-test, positioned so that their field of view covers the protected hazard.
8. Each detector shall be supplied with a manufacturer's test/calibration certificate; the bidder shall state the calibration gas, calibration interval and expected sensor life.
Make: Pioneer Industrial Instruments, Pune, or approved equivalent.

FAQ

Questions about Gas Transmitters.

Anything else? Call or WhatsApp +91 93700 39974.

Which sensor type should I specify for each gas?

For flammable gases measured as %LEL, use catalytic bead sensors, or infrared where the area may run short of oxygen or contain silicone or sulphur compounds that poison catalytic beads. Use electrochemical cells for toxic gases such as CO, H2S and SO2, and for oxygen. Infrared suits CO2, hydrocarbons and many refrigerants, and PID suits VOCs. Semiconductor sensors are low-cost but less selective.

At what height should gas detectors be mounted?

Mount according to the gas density relative to air. Methane and hydrogen are lighter and rise, so detectors go near the ceiling. LPG, propane, butane and most refrigerants are heavier and collect low, so detectors go about 300 mm above the floor. CO mixes with air and is monitored in the breathing zone. Always place detectors close to likely leak sources and consider air movement in the room.

How often should a fixed gas detector be calibrated?

Follow the site safety procedure and the manufacturer's interval, which is commonly every three to six months for toxic and flammable gas sensors. Calibrate with a certified test gas of known concentration, and bump test more often where the risk is high. Electrochemical cells have a finite life and must be replaced when they no longer respond correctly to calibration gas.

What is the difference between a gas transmitter and a gas leak detector?

A gas transmitter is a fixed instrument that measures concentration continuously at one point and sends a signal to a control system, so it protects an area around the clock. A gas leak detector is the broader term: it includes simple fixed leak alarms and portable or ultrasonic instruments used to trace where a leak is coming from during maintenance and inspection.

Should I choose a UV, IR or UV/IR flame detector?

UV detectors respond fastest and are not affected by sunlight, but welding, lightning and other UV sources can trigger them. IR detectors are less prone to false alarms from these sources but respond more slowly and can be affected by hot objects. UV/IR and multi-spectrum IR detectors cross-check more than one band and give the best false-alarm immunity for outdoor and industrial areas.