Pressure Instruments · PI
Digital Pressure Gauges — Battery-Powered, Backlit Display
Pioneer supplies battery-powered digital pressure gauges with a backlit display, peak hold and selectable units. The stainless steel model covers ranges from −100 kPa (vacuum) to 100 MPa at 0.5% FS accuracy, with a 316L isolation diaphragm and two AAA batteries.
- Accuracy: 0.5% FS

Overview
What it does and where it fits.
A digital gauge gives a numeric reading with no parallax error, so two people read the same value. That makes it useful for commissioning, testing and checking pressure at points where an analogue dial is hard to read. Units can be switched at the push of a button, and peak hold captures the highest pressure during a test or start-up.
The stainless steel model has a 316L isolation diaphragm and suits all media compatible with SS 316. It covers gauge, absolute and sealed gauge pressure. A compact 63 mm model with an ABS case and rubber boot is also available for general-purpose and test use.
Where a continuous signal to a BMS, PLC or SCADA system is needed, use a pressure transmitter instead. A digital gauge is a local indicator.
Types
- Stainless steel digital gaugeStainless shell and 316L isolation diaphragm, 0.5% FS, gauge, absolute or sealed gauge reference.
- Compact 63 mm digital gaugeABS case with silicone rubber boot, 1/4" NPT SS connection, ±1% accuracy (±0.5% optional).
Features
- No parallax error: clear numeric reading
- Selectable pressure units
- Peak (maximum) pressure hold
- Reset to zero (tare)
- Backlit display
- Auto shut-off to save battery
- 316L isolation diaphragm
- Runs on 2 × AAA batteries
Applications
- Test and measurement, calibration checks
- Process monitoring at local points
- Hydraulic and pneumatic systems
- HVAC/R diagnostics and commissioning
- Laboratory pressure measurement
Specifications
Spec table.
Standard ranges and materials. Tell us your medium, range and connection and we will match the model.
| Parameter | Value |
|---|---|
| Pressure range | −100 kPa (vacuum) to 100 MPa; spans from 0–10 kPa |
| Pressure reference | Gauge, absolute, sealed gauge |
| Accuracy | 0.5% FS |
| Over-pressure | 150% FS |
| Long-term stability | ±0.2% FS per year (typical) |
| Sampling rate | 5 per second |
| Operating temperature | −10 °C to 70 °C |
| Compensated temperature | 0 °C to 60 °C |
| Backlight | Blue |
| Electrical protection | Designed against electromagnetic interference |
| Battery | 2 × AAA |
| Materials | Stainless steel shell; 316L isolation diaphragm |
| Media | All media compatible with SS 316 |
Compact 63 mm digital gauge
| Parameter | Value |
|---|---|
| Case size | 63 mm (2.5") |
| Case material | ABS, with silicone rubber boot |
| Display | LCD, 48 × 16 mm; 4 digits (5 digits on the highest ranges) |
| Ranges | Vacuum, compound and positive ranges from −15 psi up to 0–15,000 psi |
| Units | Selectable, including psi, bar, mbar, kPa, MPa, kgf/cm², mmHg |
| Accuracy | ±1% (±0.5% optional on ranges up to 10,000 psi) |
| Proof / burst pressure | 200% / 300% FS |
| Connection | 1/4" NPT, SS 304, bottom |
| Sensor | 316L welded diaphragm, piezo-resistive |
| Operating life | 1 million cycles |
| Power | 2 × AAA (1.5 V); about 2 years in auto shut-off mode |
| Power mode | Auto or manual shut-off |
| Display refresh | Up to 3 Hz |
| Operating temperature | −10 °C to 50 °C |
| Storage temperature | −20 °C to 75 °C |
| Enclosure | IP 60 |
Other ranges and connections on request.
For consultants
Consultant spec clause.
Paste it into your technical specification or BOQ, then adjust ranges and quantities to your schedule.
1. Digital pressure gauges shall be battery-powered with backlit digital display, selectable engineering units, peak hold and zero (tare) function. 2. Pressure sensing element shall be isolated by a 316L stainless steel diaphragm; wetted parts shall be compatible with SS 316. 3. Accuracy shall be 0.5% of full scale, with over-pressure capability of 150% FS and long-term stability of ±0.2% FS per year. 4. Range shall be as scheduled between −100 kPa and 100 MPa; pressure reference gauge (absolute or sealed gauge where specified). 5. Housing shall be stainless steel; operating temperature −10 °C to 70 °C. 6. Power supply shall be 2 × AAA batteries with auto shut-off. 7. Process connection shall be bottom entry, size and thread as scheduled (1/4" NPT for compact gauges). 8. Each gauge shall be supplied with a manufacturer's test certificate. Make: Pioneer Industrial Instruments, Pune, or approved equivalent.
Is a digital pressure gauge more accurate than an analogue gauge?
Usually, yes. Pioneer's stainless digital gauge is 0.5% FS, against ±1% FSD for a standard Bourdon gauge, and the numeric display removes parallax and reading errors. An analogue ±0.25% test gauge can still match or beat a general-purpose digital gauge, though. Compare the stated accuracy class, not the number of digits on the display.
What is the difference between gauge, absolute and sealed gauge pressure?
Gauge pressure is measured relative to local atmospheric pressure and is what most process and HVAC readings use. Absolute pressure is measured from a perfect vacuum and is needed for vacuum processes and vapour-pressure work. Sealed gauge uses a fixed reference sealed inside the sensor, which suits high ranges where small atmospheric changes do not matter. Pioneer's stainless digital gauge is available in all three.
How long do the batteries last?
Battery life depends on the backlight and on whether the display is left on. The compact 63 mm model is rated at about two years on two AAA cells in auto shut-off mode. Keeping the display on continuously, or using the backlight a lot, shortens this. Carry spares for test kits and replace weak cells before a critical test.
Can a digital pressure gauge send a signal to a BMS or PLC?
The digital gauges on this page are battery-powered local indicators, without an analogue output. For a 4–20 mA signal to a BMS, PLC or SCADA system, specify a pressure transmitter, and if a local reading is also needed, a transmitter with an integral digital display. For alarms or pump control, use a pressure switch.