4 instrument types · Industrial instruments
Gas Detection and Indoor Air Quality Monitors
Pioneer supplies gas detection and indoor air quality instruments for buildings and industrial plants: CO sensors for car parks, CO2 and multi-parameter IAQ sensors for demand-controlled ventilation, air flow and velocity transmitters for fans and ducts, and fixed gas transmitters, gas leak detectors and flame detectors for plant safety.

Which to choose
Match the job to the instrument.
A quick guide. Send your data sheet and we will confirm the model.
| If you need to… | Choose |
|---|---|
| Run basement car park exhaust and jet fans on demand | Electrochemical CO sensors wired to the fan controller |
| Control outdoor air by occupancy in offices, schools and halls | NDIR CO2 sensor for demand-controlled ventilation |
| Monitor comfort and pollutants for the BMS or green building credits | Multi-parameter IAQ sensor (CO2, T, RH, PM2.5, TVOC) |
| Measure air flow across a centrifugal fan or in a duct | Air flow and velocity transmitter (MEMS, m³/h, l/s or m/s) |
| Detect LPG, natural gas or hydrogen leaks in a gas bank or kitchen | Combustible gas transmitter (%LEL) |
| Detect refrigerant leaks in a chiller plant room | Refrigerant gas detector |
| Detect fires quickly in fuel stores, hangars or open plant | UV/IR or multi-spectrum IR flame detector |
Overview
How we supply gas detection & iaq.
This range covers two jobs. The first is ventilation and comfort in occupied buildings: CO2, temperature, humidity and particulate sensors tell the BMS how much outdoor air to bring in, and air flow transmitters confirm that fans and ducts are delivering it. The second is safety: CO sensors stage car park fans, and fixed gas and flame detectors warn of leaks and fires in plant rooms, gas banks and process areas.
Most of these instruments are transmitters wired to a BMS, PLC or gas detection panel, with 4–20 mA, 0–10 V or RS485 Modbus outputs. Selection starts with the target gas or parameter and the decision the reading will drive, then the sensing principle, range, output and mounting.
Send the gas list, room schedule or BOQ, and Pioneer will propose suitable models with datasheets for consultant approval, typically within 48 hours. Where a detector forms part of a statutory fire, gas or life-safety system, confirm the approvals the authority having jurisdiction requires before specifying.
For consultants
Tender-ready clauses for every instrument in this category, ready to paste.
What gas detection and IAQ instruments does Pioneer supply?
Pioneer supplies carbon monoxide (CO) and carbon dioxide (CO2) sensors, multi-parameter indoor air quality sensors for CO2, temperature, humidity, particulate and VOCs, air flow and velocity transmitters for fans and ducts, fixed gas transmitters for combustible, toxic, oxygen and refrigerant gases, gas leak detectors and UV, IR and UV/IR flame detectors. Portable CO2 and oxygen monitors are also available.
Can these sensors connect to a building management system?
Yes. Fixed sensors and transmitters give 4–20 mA, 0–10 V or RS485 (Modbus) outputs, depending on the model, for direct connection to a BMS, PLC or gas detection panel. RS485 suits multi-parameter IAQ sensors because one two-wire bus carries every reading. Analogue outputs suit single-parameter control loops such as car park CO fan staging or AHU CO2 damper control.
Which projects typically need CO and CO2 sensors?
CO sensors are used wherever fuel is burned in an enclosed space: basement and multi-level car parks, boiler rooms, DG set rooms and kitchens. CO2 sensors are used in occupied spaces with variable occupancy, such as offices, classrooms, auditoriums, conference rooms and hospitals, to control outdoor air by demand. Green building ratings often require CO2 monitoring in densely occupied spaces.
How do I choose between a gas transmitter and an IAQ sensor?
Choose by purpose. An IAQ sensor measures comfort and ventilation parameters, such as CO2, temperature, humidity, particulate and VOCs, at normal indoor levels, and feeds the BMS. A gas transmitter is a safety detector for one specific hazardous gas, measured in %LEL or ppm, with alarm set points, and is usually wired to a dedicated gas detection panel.
Other categories
More instruments.
- Pressure Instruments
- Temperature Instruments
- Level Instruments
- Flow Instruments
- Environmental Monitoring
- Specialty Instruments